All Products

Browse Our Catalog

M35 Series Double Valves

External Monitoring

Website m35 series with without soft start 1507314274 1507314276
Features & Benefits
  • Proven ROSS SERPAR® Crossflow technology - control-reliable, Category 4, PL e applications, shuts-off and exhausts even when faulted
  • Pressure sensors - allow for external monitoring of valve state
  • Modular or threaded port connection - allows modular connection to air entry system
  • Integrated EEZ-ON® (soft start) module option
  • LED indicators - aid troubleshooting
  • Includes high-flow, clog-resistant silencer

The M35 Series valve is designed to supply air to a zone or entire machine/system until signaled to shut off and exhaust residual downstream pneumatic energy from the machine. Thus, reducing the hazards associated with the presence of residual energy during employee access and/or minor servicing. The safety function of the M35 Series valve is to shut off supply of pneumatic energy and to exhaust any pneumatic energy from downstream of the valve. Note that the M35 Series valve cannot exhaust pneumatic energy from downstream of obstructions such as check valves and closed center function valves.

The M35 Series valves are designed for external monitoring for safe, redundant operation of the valves. The M35 Series valves are constructed of redundant, 3/2 poppet type valves, and have an overall function of a single solenoid pilot-operated, spring return valve. Each single valve in the M35 Series valve is equipped with a solid state pressure sensor. Monitoring both of these sensors on each actuation and de-actuation of the M35 valve provides a diagnostic coverage of 99%. Monitoring of these sensors is to be done by an external monitoring system.

The function of the optional EEZ-ON® (soft start) module is to, on energization, allow outlet pressure to increase at a slower than normal rate until it reaches approximately 50% of inlet pressure, at which point the valve will then open fully to finish filling the system at full flow rate. This feature can be used to lessen the shock of sudden, rapid pressurization of cylinders, and to gradually refill the system.

[Read More...]
SOFT START:
PORT SIZE:
THREAD:
SOLENOID/SENSOR PINOUTS:
GAUGE:
SOFT START:
PORT SIZE:
THREAD:
SOLENOID/SENSOR PINOUTS:
GAUGE:
Model Description
M35S40GAEXABGA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, AB Pinout, Gauge
M35S40GAEXACGA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, AC Pinout, Gauge
M35S40GAEXCCGA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, CC Pinout, Gauge
M35S40GAEXCCXA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, CC Pinout, No Gauge
M35S40GAEXDBGA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, DB Pinout, Gauge
M35S40GAEXDCGA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, DC Pinout, Gauge
M35S40GAEXDCXA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, DC Pinout, No Gauge
M35S40NAEXAAXA M35 Series with Soft Start, 1/2 NPT 24 V DC, External Monitoring, AA Pinout, No Gauge
M35S40NAEXABGA M35 Series with Soft Start, 1/2 NPT 24 V DC, External Monitoring, AB Pinout, Gauge
M35S40NAEXACGA M35 Series with Soft Start, 1/2 NPT 24 V DC, External Monitoring, AC Pinout, Gauge
M35S40NAEXCCGA M35 Series with Soft Start, 1/2 NPT 24 V DC, External Monitoring, CC Pinout, Gauge
M35S40NAEXDBGA M35 Series with Soft Start, 1/2 NPT 24 V DC, External Monitoring, DB Pinout, Gauge
M35S40NAEXDCGA M35 Series with Soft Start, 1/2 NPT 24 V DC, External Monitoring, DC Pinout, Gauge
M35S50GAEXAAGA M35 Series with Soft Start, 3/4 BSPP 24 V DC, External Monitoring, AA Pinout, Gauge
M35S40GAEXAAXA M35 Series with Soft Start, 1/2 BSPP 24 V DC, External Monitoring, AA Pinout, No Gauge
SOFT START:
PORT SIZE:
THREAD:
SOLENOID/SENSOR PINOUTS:
GAUGE:
Previously Viewed Models
Ross controls logo