$ Electronic Data Sheet for ISYSNET 32 Point Valver Driver (PSSV32A) $ Copyright 2005 by Rockwell Automation $ Revision History $ Revision Date Change $ 1.1 19Oct2004 Original Version by Terry $ 1.2 06Jan2005 Added Rack Assemblies & Changed platform name to ISYSNET $ 1,3 06Jan2005 Fixed Config Assem125 $ 1.4 13Jun2005 Changed HomeURL & Icon Name [File] DescText = "ISYSNET PSSV32A"; CreateDate = 06-28-2004; CreateTime = 12:00:00; ModDate = 06-13-2005; ModTime = 12:00:00; Revision = 1.4; $ HomeURL = "http://www.parker.com/pneu/isysnet"; [Device] VendCode = 4; $ Vendor Code ProdType = 7; $ Product Type ProdCode = 236; $ Product Code 0xEC MajRev = 1; $ Major Rev MinRev = 1; $ Minor Rev VendName = "Parker-Hannifen, Inc."; ProdTypeStr = "General Purpose Discrete I/O"; ProdName = "PSSV32A 32pt DC Output"; Catalog = "PSSV32A"; Icon = "PSSV32A.ico"; 1_RSNetWorx_DNetTool = "RSI.DeviceNet.EDSApplet"; 1_RSNetWorx_NoAutoEnter = "Yes"; [Device Classification] Class1 = DeviceNet; [IO_Info] Default = 0X0004; $ COS is default PollInfo = 0X000F, $ compatable with all 1, $ input 1 1; $ output 1 StrobeInfo = 0X000F, $ Compatable with all 1, $ input 1 0; $ No strobe connection here COSInfo = 0X0007, $ Compatable with all 1, $ input 1 1; $ output 1 CyclicInfo = 0X000B, $ Compatable with all 1, $ input 1 1; $ output 1 Input1 = 5, $ size = 1 byte 40, $ 8 significant bits 0X000F, $ compatible with all conections "PSSV32A Produce Connection", $ name string 6, $ path length "20 04 24 65 30 03", $ assy obj, inst 44d(0x2C), attr 3 "Producing connection contains the status of the eight outputs"; Output1 = 4, $ size = 1 byte 32, $ 8 significant bits 0X000D, $ compatible with polled connection "PSSV32A Consuming Connection", $ name string 6, $ path length "20 04 24 25 30 03", $ assy obj, inst 34d(0x22), attr 3 "Consuming connection contains state of the eight outputs"; [ParamClass] MaxInst = 52; Descriptor = 0x09; $ Individual parameters are setable $ Automaticly stored in EERPOM CfgAssembly = 0x7B; $ the custom config assembly is 123d [Assembly] Assem37= "PSSV32A Consume Assembly", "", $ Path is Assy Obj Class 4 Inst 25 Attr3) 4, $ total length in bytes 0,,, $ no changes, ",,"= reserved 1, Param1, $ # bits, Value for Output #0 1, Param2, $ # bits, Value for Output #1 1, Param3, $ # bits, Value for Output #2 1, Param4, $ # bits, Value for Output #3 1, Param5, $ # bits, Value for Output #4 1, Param6, $ # bits, Value for Output #5 1, Param7, $ # bits, Value for Output #6 1, Param8, $ # bits, Value for Output #7 1, Param9, $ # bits, Value for Output #8 1, Param10, $ # bits, Value for Output #9 1, Param11, $ # bits, Value for Output #10 1, Param12, $ # bits, Value for Output #11 1, Param13, $ # bits, Value for Output #12 1, Param14, $ # bits, Value for Output #13 1, Param15, $ # bits, Value for Output #14 1, Param16, $ # bits, Value for Output #15 1, Param17, $ # bits, Value for Output #16 1, Param18, $ # bits, Value for Output #17 1, Param19, $ # bits, Value for Output #18 1, Param20, $ # bits, Value for Output #19 1, Param21, $ # bits, Value for Output #20 1, Param22, $ # bits, Value for Output #21 1, Param23, $ # bits, Value for Output #22 1, Param24, $ # bits, Value for Output #23 1, Param25, $ # bits, Value for Output #24 1, Param26, $ # bits, Value for Output #25 1, Param27, $ # bits, Value for Output #26 1, Param28, $ # bits, Value for Output #27 1, Param29, $ # bits, Value for Output #28 1, Param30, $ # bits, Value for Output #29 1, Param31, $ # bits, Value for Output #30 1, Param32, $ # bits, Value for Output #31 0,; $ Pad bits none, all used Assem101= "PSSV32A Produce Assembly", "", $ Path is Assy Obj Class 4 Inst 65 Attr3) 5, $ total length in bytes 0,,, $ no changes, ",,"= reserved 1, Param1, $ # bits, Value for Output #0 1, Param2, $ # bits, Value for Output #1 1, Param3, $ # bits, Value for Output #2 1, Param4, $ # bits, Value for Output #3 1, Param5, $ # bits, Value for Output #4 1, Param6, $ # bits, Value for Output #5 1, Param7, $ # bits, Value for Output #6 1, Param8, $ # bits, Value for Output #7 1, Param9, $ # bits, Value for Output #8 1, Param10, $ # bits, Value for Output #9 1, Param11, $ # bits, Value for Output #10 1, Param12, $ # bits, Value for Output #11 1, Param13, $ # bits, Value for Output #12 1, Param14, $ # bits, Value for Output #13 1, Param15, $ # bits, Value for Output #14 1, Param16, $ # bits, Value for Output #15 1, Param17, $ # bits, Value for Output #16 1, Param18, $ # bits, Value for Output #17 1, Param19, $ # bits, Value for Output #18 1, Param20, $ # bits, Value for Output #19 1, Param21, $ # bits, Value for Output #20 1, Param22, $ # bits, Value for Output #21 1, Param23, $ # bits, Value for Output #22 1, Param24, $ # bits, Value for Output #23 1, Param25, $ # bits, Value for Output #24 1, Param26, $ # bits, Value for Output #25 1, Param27, $ # bits, Value for Output #26 1, Param28, $ # bits, Value for Output #27 1, Param29, $ # bits, Value for Output #28 1, Param30, $ # bits, Value for Output #29 1, Param31, $ # bits, Value for Output #30 1, Param32, $ # bits, Value for Output #31 1, Param33, $ Status of Outputs 0-3 1, Param34, $ Status of Outputs 4-7 1, Param35, $ Status of Outputs 8-11 1, Param36, $ Status of Outputs 12-15 1, Param37, $ Status of Outputs 16-19 1, Param38, $ Status of Outputs 20-23 1, Param39, $ Status of Outputs 24-27 1, Param40, $ Status of Outputs 28-31 0,; $ Pad bits Assem123 = "PSSV32A Configuration Assembly", "", $ Path is implied (Assy obj attr3) 2, $ total length in bytes 0,,, $ changes, ",,"= reserved 1,Param45, $ # bits, Fault State selection 1,Param46, $ # bits, Fault Value selection 1,Param47, $ # bits, Idle State selection 1,Param48, $ # bits, Idle Value selection 1,Param42, $ # bits, Output Latch selection 3,, $ pad bits none, all used 8,; $ pad byte (for word boundary) Assem124 = $ Private config in Forward Open, Module "3rd Party Private Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved 16,Param121, $ configuration revision (only valid value is 1) 16,; $ reserved - zeros Assem125 = $ Private config in Forward Open, Module "Adapter Config Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved 16,Param122, $ Non-Logix Header (constant 0x7001) 16,1_RackSize, $ number of slots 16,Param121, $ configuration revision (only valid value is 1) 16,; $ reserved - zeros Assem126 = $ O2T (output data) "Ouput Data Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved ,Assem37; $ Assembly sent to module Assem127 = $ T2O (input data) "Input Data Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved 32,, $ Fault bits ,Assem101; $ Assembly passed from module $ ProxiedAssem1 = $ "DC Output Rack Configuration Assembly", $ "01 SLOT 20 04 24 78 30 03", $ Path to Assy Obj (4) inst 120d attr 3 $ , $ total length in bytes $ 0x0000, $ descriptor $ ,, $ ",,"= reserved $ Contents of Assem120 $ x,Param, $ Group ... $ x,; $ Pad bit $ ProxiedAssem3 = $ "Real Time Input Format", $ , $ No Path $ , $ Length $ 0x0000, $ Descriptor $ ,, $ ",,"= reserved $ 8,Assem101; $ ProxiedAssem4 = $ "Real Time Output Format", $ , $ No Path $ , $ Length $ 0x0000, $ Descriptor $ ,, $ ",,"= reserved $ 8,Assem37; [Params] $ Output state Param1 = $ Value for Output #0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #0", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param2 = $ Value for Output #1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #1", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param3 = $ Value for Output #2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #2", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param4 = $ Value for Output #3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #3", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param5 = $ Value for Output #4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #4", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param6 = $ Value for Output #5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #5", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param7 = $ Value for Output #6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #6", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param8 = $ Value for Output #7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #7", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param9 = $ Value for Output #8 0, $ reserved 6, $ Link Path Size "20 09 24 09 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #8", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param10 = $ Value for Output #9 0, $ reserved 6, $ Link Path Size "20 09 24 0A 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #9", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param11 = $ Value for Output #10 0, $ reserved 6, $ Link Path Size "20 09 24 0B 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #10", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param12 = $ Value for Output #11 0, $ reserved 6, $ Link Path Size "20 09 24 0C 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #11", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param13 = $ Value for Output #12 0, $ reserved 6, $ Link Path Size "20 09 24 0D 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #12", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param14 = $ Value for Output #13 0, $ reserved 6, $ Link Path Size "20 09 24 0E 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #13", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param15 = $ Value for Output #14 0, $ reserved 6, $ Link Path Size "20 09 24 0F 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #14", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param16 = $ Value for Output #15 0, $ reserved 6, $ Link Path Size "20 09 24 10 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #15", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param17 = $ Value for Output #16 0, $ reserved 6, $ Link Path Size "20 09 24 11 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #16", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param18 = $ Value for Output #17 0, $ reserved 6, $ Link Path Size "20 09 24 12 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #17", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param19 = $ Value for Output #18 0, $ reserved 6, $ Link Path Size "20 09 24 13 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #18", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param20 = $ Value for Output #19 0, $ reserved 6, $ Link Path Size "20 09 24 14 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #19", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param21 = $ Value for Output #20 0, $ reserved 6, $ Link Path Size "20 09 24 15 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #20", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param22 = $ Value for Output #21 0, $ reserved 6, $ Link Path Size "20 09 24 16 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #21", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param23 = $ Value for Output #22 0, $ reserved 6, $ Link Path Size "20 09 24 17 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #22", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param24 = $ Value for Output #23 0, $ reserved 6, $ Link Path Size "20 09 24 18 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #23", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param25 = $ Value for Output #24 0, $ reserved 6, $ Link Path Size "20 09 24 19 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #24", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param26 = $ Value for Output #25 0, $ reserved 6, $ Link Path Size "20 09 24 1A 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #25", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param27 = $ Value for Output #26 0, $ reserved 6, $ Link Path Size "20 09 24 1B 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #26", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param28 = $ Value for Output #27 0, $ reserved 6, $ Link Path Size "20 09 24 1C 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #27", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param29 = $ Value for Output #28 0, $ reserved 6, $ Link Path Size "20 09 24 1D 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #28", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param30 = $ Value for Output #29 0, $ reserved 6, $ Link Path Size "20 09 24 1E 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #29", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param31 = $ Value for Output #30 0, $ reserved 6, $ Link Path Size "20 09 24 1F 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #30", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param32 = $ Value for Output #31 0, $ reserved 6, $ Link Path Size "20 09 24 20 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #31", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $ Output Status Param33 = $ Status of Outputs 0-3 0, $ reserved 6, $ Link Path Size "20 0F 24 01 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 0-3", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param34 = $ Status of Outputs 4-7 0, $ reserved 6, $ Link Path Size "20 0F 24 02 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 4-7", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param35 = $ Status of Outputs 8-11 0, $ reserved 6, $ Link Path Size "20 0F 24 03 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 8-11", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param36 = $ Status of Outputs 12-15 0, $ reserved 6, $ Link Path Size "20 0F 24 04 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 12-15", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param37 = $ Status of Outputs 16-19 0, $ reserved 6, $ Link Path Size "20 0F 24 05 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 16-19", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param38 = $ Status of Outputs 20-23 0, $ reserved 6, $ Link Path Size "20 0F 24 06 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 20-23", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param39 = $ Status of Outputs 24-27 0, $ reserved 6, $ Link Path Size "20 0F 24 07 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 24-27", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param40 = $ Status of Outputs 28-31 0, $ reserved 6, $ Link Path Size "20 0F 24 08 30 01", $ Link Path to parater object's fault status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Outputs 28-31", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - short circuit\n - over current\n - over temp\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $ Group Status Param41 = $ Status of Output Group 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 05", $ Link Path to DOG object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xD1, $ Data Type - 8 bit String (New data type) 1, $ Data Size "Output Fault Status", $ Parameter Name "", $ Units String "This Status byte is the OR of all possible faults for ALL channels.\n\nPossible Faults:\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,255,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum41 = 0,"Outputs 0-3 Fault", 1,"Outputs 4-7 Fault", 2,"Outputs 8-11 Fault", 3,"Outputs 12-15 Fault", 4,"Outputs 16-19 Fault", 5,"Outputs 20-23 Fault", 6,"Outputs 24-27 Fault", 7,"Outputs 28-31 Fault"; $ Enable Latched Alarms Param42 = $ Enable Latched Alarms all 32 outputs 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms 32 Outputs", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $ Clear Latched Alarm Param43 = $ Clear latached alarms all 32 outputs 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms 32 Outputs", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $ Group Run/Idle Command Param44 = $ Group Run/Idle Command 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 06", $ Link Path to DOG object's Command Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Group Run/Idle Command", $ Parameter Name "", $ Units String "Puts all outputs in Idle mode.\nOutput state will be determined by the Idle State parameter. \nNote: Only works when NOT in a scanner's scanlist.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $ Fault Values Param45 = $ Fault State selection for 32 outputs 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 07", $ Link Path to DOG object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Action 32 Outputs", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param46 = $ Fault Value selection for 32 outputs 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 08", $ Link Path to DOG object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value 32 Outputs", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $ Idle Values Param47 = $ Idle State selection for output 0 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 09", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action 32 Outputs", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param48 = $ Idle Value selection for output 0 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 0A", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value 32 Outputs", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $ Autobaud Param49 = $ Disable Autobaud 0, $ reserved 6, $ Link Path Size "20 03 24 01 30 64", $ Link Path to disable autobaud attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Autobaud", $ Parameter Name "", $ Units String "Autobaud allows module to match the baud rate of existing devices on a network.\n\nChanges to this attribute take effect after next powerup.\nIf 'enabled', the Baud Rate Attribute can not be set.", 0,1,0, $ Min, Max, and Default values 1,1,1,0,0,0,0,0,0; $ Not Used $Point Object stuff Param50 = $ AutoAddress 0, $ reserved 7, $ Link Path Size "21 12 03 24 01 30 03", $ Link Path to AutoAddress attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Sequential AutoAddress", $ Parameter Name "", $ Units String "Sequential AutoAddress will re-assign the node address of ever module to the right.\nEach module will change it's node address to one greater than then it's neighbor.\n\nMAKE SURE THE NODE ADDRESS OF THIS MODULE IS THE DESIRED VALUE BEFORE ISSUING THIS COMMAND.\n\nWhen this command is set, each module to the right will get a new address one greater than it's neighbor.\nThe address will ripple through a line of ISYSNET I/O modules.\n\nSteps to Auto Address a line of ISYSNET I/O modules:\n 1.) Set the address of the first module (next to PDN or adapter).\n 2.) Send the Auto Address command to 'Sequential Address.'\n 3.) All modules in line will reset with new sequential addresses.\n\nExample:\nIf there are 5 ISYSNET modules in a line, and the address of the first module is 10.\nAfter the 'Sequential Address' command is sent to the first module, the node address of the line will be:\n 10, 11, 12, 13, and 14.", 0,1,0, $ Min, Max, and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param51 = $ Baud Rate 0, $ reserved 7, $ Link Path Size "21 12 03 24 01 30 05", $ Link Path to Baud Rate attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC6, $ Data Type - byte (New data type) 1, $ Data Size "Broadcast Baud Rate", $ Parameter Name "", $ Units String "This command will change the baud rate of this and every module to the right\nto the value indicated.\nIf AutoBaud is ENABLED, this command will not change the operation of the module at power up.", 0,3,0, $ Min, Max, and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param52 = $ Set Disable AutoBaud 0, $ reserved 7, $ Link Path Size "21 12 03 24 01 30 06", $ Link Path to Disable AutoBaud attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC6, $ Data Type - byte (New data type) 1, $ Data Size "Broadcast AutoBaud", $ Parameter Name "", $ Units String "This command will change the AutoBaud attribute of this and every module to the right\nto the value indicated.\nIf AutoBaud is 'disabled,' the Baud Rate parameter will set the baud rate next time the module is powered up.", 0,2,0, $ Min, Max, and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Param121 = $ Revision of Configuration Assembly 0, $ first field shall equal 0 ,, $ path size,path 0x0210, $ descriptor (readonly, no display) 0xC7, $ data type : 16-bit Unsigned Integer 2, $ data size in bytes "Configuration revision", $ name "", $ units "", $ help string 1,1,1, $ min,max,default data values 0,0,0,0, $ mult,dev,base,offset scaling not used 0,0,0,0, $ mult,dev,base,offset link not used 0; $ decimal places not used Param122 = $ non-Logix header 0, $ first field shall equal 0 ,, $ path size,path 0x0210, $ descriptor (readonly, no display) 0xC7, $ data type : 16-bit Unsigned Integer 2, $ data size in bytes "Non-Logix Header", $ name "", $ units "", $ help string 0x7001,0x7001,0x7001, $ min,max,default data values 0,0,0,0, $ mult,dev,base,offset scaling not used 0,0,0,0, $ mult,dev,base,offset link not used 0; $ decimal places not used [EnumPar] Param1 = "OFF","ON"; $ output value 0 Param2 = "OFF","ON"; $ output value 1 Param3 = "OFF","ON"; $ output value 2 Param4 = "OFF","ON"; $ output value 3 Param5 = "OFF","ON"; $ output value 4 Param6 = "OFF","ON"; $ output value 5 Param7 = "OFF","ON"; $ output value 6 Param8 = "OFF","ON"; $ output value 7 Param9 = "OFF","ON"; $ output value 8 Param10 = "OFF","ON"; $ output value 9 Param11 = "OFF","ON"; $ output value 10 Param12 = "OFF","ON"; $ output value 11 Param13 = "OFF","ON"; $ output value 12 Param14 = "OFF","ON"; $ output value 13 Param15 = "OFF","ON"; $ output value 14 Param16 = "OFF","ON"; $ output value 15 Param17 = "OFF","ON"; $ output value 16 Param18 = "OFF","ON"; $ output value 17 Param19 = "OFF","ON"; $ output value 18 Param20 = "OFF","ON"; $ output value 19 Param21 = "OFF","ON"; $ output value 20 Param22 = "OFF","ON"; $ output value 21 Param23 = "OFF","ON"; $ output value 22 Param24 = "OFF","ON"; $ output value 23 Param25 = "OFF","ON"; $ output value 24 Param26 = "OFF","ON"; $ output value 25 Param27 = "OFF","ON"; $ output value 26 Param28 = "OFF","ON"; $ output value 27 Param29 = "OFF","ON"; $ output value 28 Param30 = "OFF","ON"; $ output value 29 Param31 = "OFF","ON"; $ output value 30 Param32 = "OFF","ON"; $ output value 31 Param33 = "No Fault","FAULT"; $ outputs 0-3 status Param34 = "No Fault","FAULT"; $ outputs 4-7 status Param35 = "No Fault","FAULT"; $ outputs 8-11 status Param36 = "No Fault","FAULT"; $ outputs 12-15 status Param37 = "No Fault","FAULT"; $ outputs 16-19 status Param38 = "No Fault","FAULT"; $ outputs 20-23 status Param39 = "No Fault","FAULT"; $ outputs 24-27 status Param40 = "No Fault","FAULT"; $ outputs 28-31 status Param41 = "No Fault","FAULT"; $ output group status Param42 = "Latching Disabled","Latching Enabled"; $ Latch alarms Param43 = "Do Nothing","Clear Alarms"; $ clear Alarms Param44 = "Idle","Run"; $ Run/Idle command Param45 = "Fault Value","Hold Last State"; $ fault action Param46 = "OFF","ON"; $ fault value Param47 = "Idle Value","Hold Last State"; $ idle action Param48 = "OFF","ON"; $ idle value Param49 = "Enable","Disable"; $ Autobaud Param50 = "Do Nothing","Sequential Address"; $ Auto address Param51 = "Do Nothing","125 kHz","250 kHz", $ baud rate "500 kHz"; Param52 = "Do Nothing","Enable","Disable"; $ Autobaud [Groups] Group1 = "I/O - Output Value", 32, 1,2,3,4,5,6,7,8,9,10,11,12,13, 14,15,16,17,18,19,20,21,22,23,24, 25,26,27,28,29,30,31,32; $ Output Value Group2 = "I/O - Output Status", 8,33,34,35,36,37,38,39,40; $ Output Status Group3 = "I/O - Output Group Status", 1, 41; $ Output group status Group4 = "Reset Services", 2, 43,44; $ reset latch, run/idle (faulted outs) Group5 = "Configuration", 6,42,45,46,47,48,49; $ latch, fault, idle, autobaud Group6 = "ISYSNET Bus", 3, 50,51,52; $dup mac, qc, autoaddr, brate, auto baud [Connection Manager] Connection1 = $ Exclusive Owner (Direct to Module) $ Catalogs 32 valve module $ Config Assem 123 $ Consume Assem 37 $ Produce Assem 101 0x04030002, $ trigger & transport 0x44240405, $ point/multicast & priority & realtime format ,,Assem126, $ O=>T default,description ,,Assem127, $ T=>O default,description ,Assem124, $ config part 1 ,Assem123, $ config part 2 (module configuration) "Direct Exclusive Owner", $ connection name "Direct Exclusive Owner Connection - Output data controls the state of each of the outputs. Input data contains status of each of the outputs.", $ Help string "20 04 24 7B 2C 25 2C 65"; $ Connection2 = $ There is NO Input Only (Direct to Module) Connection3 = $ Listen Only (Direct to Module) $ Catalogs 32 valve module $ Config Assem 123 $ Consume Assem 0xBF (Listen Only) $ Produce Assem 101 0x01030002, $ trigger & transport 0x44240305, $ point/multicast & priority & realtime format ,0,, $ O=>T default,description ,,Assem127, $ T=>O default,description ,Assem124, $ config part 1 ,, $ config part 2 (module configuration) "Direct Listen Only", $ connection name "Direct Listen Only Connection - Input data contains the STATUS of each of the outputs. There is NO output data.", $ Help string "20 04 24 7B 2C BF 2C 65"; [Port] Port1 = DeviceNet, $ or maybe 1_Virtual_Backplane "ISYSNET Backplane", $ Name of backplane "20 03 24 01", $ Path to DeviceNet Object Instance 1 1; $ Port number 1 [Modular] Width = 1; $ I/O Module EDS $ Number of slots in rack = Product Code - 199 $ Number of I/O modules in rack = Product Code - 200 $ Note Rack# does not match in Adapter EDS, Adapter EDS includes one for Slot 0 Rack1 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 201, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1; $ Legal Slots Rack2 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 202, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1,2; $ Legal Slots Rack3 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 203, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1,2,3; $ Legal Slots Rack4 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 204, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1,2,3,4; $ Legal Slots Rack5 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 205, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1,2,3,4,5; $ Legal Slots Rack6 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 206, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1,2,3,4,5,6; $ Legal Slots Rack7 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 207, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1,2,3,4,5,6,7; $ Legal Slots Rack8 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 208, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1,2,3,4,5,6,7,8,9;$ Legal Slots Rack9 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 209, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10; $ Legal Slots Rack10 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 210, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11; $ Legal Slots Rack11 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 211, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12; $ Legal Slots Rack12 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 212, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13; $ Legal Slots Rack13 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 213, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14; $ Legal Slots Rack14 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 214, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15; $ Legal Slots Rack15 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 215, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16; $ Legal Slots Rack16 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 216, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17; $ Legal Slots Rack17 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 217, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18; $ Legal Slots Rack18 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 218, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19; $ Legal Slots Rack19 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 219, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20; $ Legal Slots Rack20 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 220, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21; $ Legal Slots Rack21 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 221, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22; $ Legal Slots Rack22 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 222, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23; $ Legal Slots Rack23 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 223, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24; $ Legal Slots Rack24 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 224, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25; $ Legal Slots Rack25 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 225, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26; $ Legal Slots Rack26 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 226, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27; $ Legal Slots Rack27 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 227, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28; $ Legal Slots Rack28 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 228, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29; $ Legal Slots Rack29 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 229, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30; $ Legal Slots Rack30 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 230, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31; $ Legal Slots Rack31 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 231, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32; $ Legal Slots Rack32 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 232, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33; $ Legal Slots Rack33 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 233, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34; $ Legal Slots Rack34 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 234, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35; $ Legal Slots Rack35 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 235, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36; $ Legal Slots Rack36 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 236, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37; $ Legal Slots Rack37 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 237, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38; $ Legal Slots Rack38 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 238, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39; $ Legal Slots Rack39 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 239, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40; $ Legal Slots Rack40 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 240, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41; $ Legal Slots Rack41 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 241, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42; $ Legal Slots Rack42 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 242, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43; $ Legal Slots Rack43 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 243, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44; $ Legal Slots Rack44 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 244, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45; $ Legal Slots Rack45 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 245, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46; $ Legal Slots Rack46 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 246, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47; $ Legal Slots Rack47 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 247, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48; $ Legal Slots Rack48 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 248, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49; $ Legal Slots Rack49 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 249, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50; $ Legal Slots Rack50 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 250, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51; $ Legal Slots Rack51 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 251, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52; $ Legal Slots Rack52 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 252, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53; $ Legal Slots Rack53 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 253, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54; $ Legal Slots Rack54 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 254, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55; $ Legal Slots Rack55 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 255, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56; $ Legal Slots Rack56 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 256, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57; $ Legal Slots Rack57 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 257, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58; $ Legal Slots Rack58 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 258, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59; $ Legal Slots Rack59 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 259, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60; $ Legal Slots Rack60 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 260, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60, 61; $ Legal Slots Rack61 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 261, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60, 61,62; $ Legal Slots Rack62 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 262, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60, 61,62,63; $ Legal Slots Rack63 = $ Based on the virtual backplane (VB5FL) 4, $ VendorID = Parker 0x6C, 263, $ Product Type, Product Code 1, 1, $ Major Revision, Minor Revision ,,, $ Reserved 1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40, 41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60, 61,62,63,64; $ Legal Slots ExternalID = "EC 00 81 01"; $ Product Code (Low, High), Compatable bit (8),Maj Rev, Min Rev