$ Electronic Data Sheet for ISYSNET (PSST8M8A) $ Copyright 2005 by Rockwell Automation $ Universal version for: DeviceNet, ControlNet, and EthernetIP $ Revision History $ Revision Date Change $ 1.1 01Dec2004 Started with revision 2.1 of 1738-OB8EM8 30Nov04 $ Change IDs to Parker $ 1.2 26Aug2004 Changed product code to 201 $ 1.3 22Sep2004 Changed VendID in Rack def $ 1.4 01Dec2004 name change, home URL $ Added Assem124 - Changed CNXNs for 3rd Party $ 1.5 04Jan2005 Changed platform name to ISYSNET $ 1.6 13Jun2005 Changed HomeURL & Icon Name [File] DescText = "ISYSNET PSST8M8A"; CreateDate = 04-23-2003; CreateTime = 12:00:00; ModDate = 06-13-2005; ModTime = 12:00:00; Revision = 1.6; $ HomeURL = "http://www.parker.com/pneu/isysnet"; [Device] VendCode = 4; $ Vendor Code ProdType = 7; $ Product Type ProdCode = 211; $ Product Code MajRev = 3; $ Major Rev MinRev = 10; $ Minor Rev VendName = "Parker Hannifin Company, Inc."; ProdTypeStr = "General Purpose Discrete I/O"; ProdName = "PSST8M8A 8OUT DIG SOURCE M8"; Catalog = "PSST8M8A"; Icon = "PSST8M8A.ico"; 1_RSNetWorx_DNetTool = "RSI.DeviceNet.EDSApplet"; 1_RSNetWorx_NoAutoEnter = "Yes"; [Device Classification] Class1 = DeviceNet; [IO_Info] Default = 0X0004; $ COS is default PollInfo = 0X000F, $ compatable with all 1, $ input 1 1; $ output 1 StrobeInfo = 0X000F, $ Compatable with all 1, $ input 1 0; $ No strobe connection here COSInfo = 0X0007, $ Compatable with all 1, $ input 1 1; $ output 1 CyclicInfo = 0X000B, $ Compatable with all 1, $ input 1 1; $ output 1 Input1 = 1, $ size = 1 byte 8, $ 8 significant bits 0X000F, $ compatible with all conections "PSST8M8A Produce Connection", $ name string 6, $ path length "20 04 24 2C 30 03", $ assy obj(4), inst 44d(0x2C), attr 3 "Producing connection contains the status of the eight outputs"; Output1 = 1, $ size = 1 byte 8, $ 8 significant bits 0X000D, $ compatible with polled connection "PSST8M8A Consuming Connection", $ name string 6, $ path length "20 04 24 22 30 03", $ assy obj(4), inst 34d(0x22), attr 3 "Consuming connection contains state of the eight outputs"; [ParamClass] MaxInst = 122; Descriptor = 0x09; $ Individual parameters are setable $ Automaticly stored in EERPOM CfgAssembly = 0x7B; $ the custom config assembly is 123d(0x7B) [Assembly] Assem34= "PSST8M8A Consume Assembly", "", $ Path is (assy obj.(4), inst 34d(0x22), attr 3) 1, $ total length in bytes 0,,, $ no changes, ",,"= reserved 1, Param1, $ # bits, Value for Output #0 1, Param2, $ # bits, Value for Output #1 1, Param3, $ # bits, Value for Output #2 1, Param4, $ # bits, Value for Output #3 1, Param5, $ # bits, Value for Output #4 1, Param6, $ # bits, Value for Output #5 1, Param7, $ # bits, Value for Output #6 1, Param8 $ # bits, Value for Output #7 ; $ Pad bits none, all used Assem44= "PSST8M8A Produce Assembly", "", $ Path is (assy obj(4), inst 44d(0x2C), attr 3) 1, $ total length in bytes 0,,, $ no changes, ",,"= reserved 1, Param9, $ # bits, Status of Output 0 1, Param10, $ # bits, Status of Output 1 1, Param11, $ # bits, Status of Output 2 1, Param12, $ # bits, Status of Output 4 1, Param13, $ # bits, Status of Output 5 1, Param14, $ # bits, Status of Output 6 1, Param15, $ # bits, Status of Output 7 1, Param16 $ # bits, Status of Output 8 ; $ no Pad bits Assem123 = "PSST8M8A Configuration Assembly", "", $ Path is (assy obj.(4) inst 123d(0x7B), attr 3) 8, $ total length in bytes 0,,, $ no changes, ",,"= reserved 1,Param43, $ # bits, Fault State selection for output 0 1,Param45, $ # bits, Fault State selection for output 1 1,Param47, $ # bits, Fault State selection for output 2 1,Param49, $ # bits, Fault State selection for output 3 1,Param51, $ # bits, Fault State selection for output 4 1,Param53, $ # bits, Fault State selection for output 5 1,Param55, $ # bits, Fault State selection for output 6 1,Param57, $ # bits, Fault State selection for output 7 1,Param44, $ # bits, Fault Value selection for output 0 1,Param46, $ # bits, Fault Value selection for output 1 1,Param48, $ # bits, Fault Value selection for output 2 1,Param50, $ # bits, Fault Value selection for output 3 1,Param52, $ # bits, Fault Value selection for output 4 1,Param54, $ # bits, Fault Value selection for output 5 1,Param56, $ # bits, Fault Value selection for output 6 1,Param58, $ # bits, Fault Value selection for output 7 1,Param59, $ # bits, Idle State selection for output 0 1,Param61, $ # bits, Idle State selection for output 1 1,Param63, $ # bits, Idle State selection for output 2 1,Param65, $ # bits, Idle State selection for output 3 1,Param67, $ # bits, Idle State selection for output 4 1,Param69, $ # bits, Idle State selection for output 5 1,Param71, $ # bits, Idle State selection for output 6 1,Param73, $ # bits, Idle State selection for output 7 1,Param60, $ # bits, Idle Value selection for output 0 1,Param62, $ # bits, Idle Value selection for output 1 1,Param64, $ # bits, Idle Value selection for output 2 1,Param66, $ # bits, Idle Value selection for output 3 1,Param68, $ # bits, Idle Value selection for output 4 1,Param70, $ # bits, Idle Value selection for output 5 1,Param72, $ # bits, Idle Value selection for output 6 1,Param74, $ # bits, Idle Value selection for output 7 1,Param83, $ # bits, Enable No Load for output 0 1,Param84, $ # bits, Enable No Load for output 1 1,Param85, $ # bits, Enable No Load for output 2 1,Param86, $ # bits, Enable No Load for output 3 1,Param87, $ # bits, Enable No Load for output 4 1,Param88, $ # bits, Enable No Load for output 5 1,Param89, $ # bits, Enable No Load for output 6 1,Param90, $ # bits, Enable No Load for output 7 1,Param91, $ # bits, Reset Mode for output 0 1,Param92, $ # bits, Reset Mode for output 1 1,Param93, $ # bits, Reset Mode for output 2 1,Param94, $ # bits, Reset Mode for output 3 1,Param95, $ # bits, Reset Mode for output 0 1,Param96, $ # bits, Reset Mode for output 1 1,Param97, $ # bits, Reset Mode for output 2 1,Param98, $ # bits, Reset Mode for output 3 1,Param75, $ # bits, Enable Latched Alarms for output 0 1,Param76, $ # bits, Enable Latched Alarms for output 1 1,Param77, $ # bits, Enable Latched Alarms for output 2 1,Param78, $ # bits, Enable Latched Alarms for output 3 1,Param79, $ # bits, Enable Latched Alarms for output 4 1,Param80, $ # bits, Enable Latched Alarms for output 5 1,Param81, $ # bits, Enable Latched Alarms for output 6 1,Param82, $ # bits, Enable Latched Alarms for output 7 8,; $ pad byte (for word boundary) Assem124 = $ Private config in Forward Open, Module "3rd Party Private Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved 16,Param101, $ configuration revision (only valid value is 1) 16,; $ reserved - zeros Assem125 = $ Private config in Forward Open, Module "Adapter Config Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved 16,Param122, $ Non-Logix Header (constant 0x7001) 16,1_RackSize, $ number of slots 16,Param121, $ configuration revision (only valid value is 1) 16,; $ reserved - zeros Assem126 = $ O2T (output data) "Ouput Data Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved ,Assem34; $ Assembly sent to module Assem127 = $ T2O (input data) "Input Data Assembly", , $ Path , $ Length in bytes , $ descriptor ,, $ reserved 32,, $ Fault bits ,Assem44; $ Assembly passed from module ProxiedAssem1 = "DC Output Rack Configuration Assembly", "01 SLOT 20 04 24 78 30 03", $ Path to Assy Obj (4) inst 120d attr 3 , $ total length in bytes 0x0000, $ descriptor ,, $ ",,"= reserved 1,Param106, $ Group Fault Action 1,Param107, $ Group Fault Value 1,Param108, $ Group Idle Action 1,Param109, $ Group Idle Value 1,Param110, $ Group No Load Enable 1,Param111, $ Group Reset Mode 1,Param112, $ Group Latch Alarms 1,; $ Pad bit ProxiedAssem3 = "Real Time Input Format", , $ No Path , $ Length 0x0000, $ Descriptor ,, $ ",,"= reserved 8,Assem44; ProxiedAssem4 = "Real Time Output Format", , $ No Path , $ Length 0x0000, $ Descriptor ,, $ ",,"= reserved 8,Assem34; [Params] $ Output state Param1 = $ Value for Output #0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #0", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum1 = 0,"OFF", 1,"ON"; Param2 = $ Value for Output #1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #1", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum2 = 0,"OFF", 1,"ON"; Param3 = $ Value for Output #2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #2", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum3 = 0,"OFF", 1,"ON"; Param4 = $ Value for Output #3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #3", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum4 = 0,"OFF", 1,"ON"; Param5 = $ Value for Output #4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #4", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum5 = 0,"OFF", 1,"ON"; Param6 = $ Value for Output #5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #5", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum6 = 0,"OFF", 1,"ON"; Param7 = $ Value for Output #6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #6", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum7 = 0,"OFF", 1,"ON"; Param8 = $ Value for Output #7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 03", $ Link Path to DOP object's value attribute. 0x0022, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable and Settable. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Value #7", $ Parameter Name "", $ Units String "Value of output point. 'ON' or 'OFF'\nNOT SETTABLE when I/O conection is established.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum8 = 0,"OFF", 1,"ON"; $ Output status Param9 = $ Status of Output 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Output #0", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum9 = 0,"No Fault", 1,"FAULT"; Param10 = $ Status of Output 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Status of Output #1", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum10 = 0,"No Fault", 1,"FAULT"; Param11 = $ Status of Output 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Status of Output #2", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum11 = 0,"No Fault", 1,"FAULT"; Param12 = $ Status of Output 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean 1, $ Data Size "Status of Output #3", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum12 = 0,"No Fault", 1,"FAULT"; Param13 = $ Status of Output 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Status of Output #4", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum13 = 0,"No Fault", 1,"FAULT"; Param14 = $ Status of Output 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Status of Output #5", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum14 = 0,"No Fault", 1,"FAULT"; Param15 = $ Status of Output 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Status of Output #6", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum15 = 0,"No Fault", 1,"FAULT"; Param16 = $ Status of Output 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 04", $ Link Path to DOP object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Status of Output #7", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for this channel.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum16 = 0,"No Fault", 1,"FAULT"; $ No Load Diagnostic Param17 = $ No load status of 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #0", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum17 = 0,"No Fault", 1,"No Load Detected"; Param18 = $ No load status of 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #1", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum18 = 0,"No Fault", 1,"No Load Detected"; Param19 = $ No load status of 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #2", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum19 = 0,"No Fault", 1,"No Load Detected"; Param20 = $ No load status of 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #3", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum20 = 0,"No Fault", 1,"No Load Detected"; Param21 = $ No load status of 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #4", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum21 = 0,"No Fault", 1,"No Load Detected"; Param22 = $ No load status of 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #5", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum22 = 0,"No Fault", 1,"No Load Detected"; Param23 = $ No load status of 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #6", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum23 = 0,"No Fault", 1,"No Load Detected"; Param24 = $ No load status of 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 6B", $ Link Path to DOP object's No Load attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "No Load Status #7", $ Parameter Name "", $ Units String "No Load or Open Wire status bit.\nNo load can only be detected when the channel is in the OFF state.\nField power is required to detect Open Load.\nNo Load status must be enabled.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum24 = 0,"No Fault", 1,"No Load Detected"; $ Short/Overload Diagnostic Param25 = $ Short/Overload status of 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #0", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum25 = 0,"No Fault", 1,"Short/Overload Fault"; Param26 = $ Short/Overload status of 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #1", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum26 = 0,"No Fault", 1,"Short/Overload Fault"; Param27 = $ Short/Overload status of 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #2", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum27 = 0,"No Fault", 1,"Short/Overload Fault"; Param28 = $ Short/Overload status of 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #3", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum28 = 0,"No Fault", 1,"Short/Overload Fault"; Param29 = $ Short/Overload status of 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #4", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum29 = 0,"No Fault", 1,"Short/Overload Fault"; Param30 = $ Short/Overload status of 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #5", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum30 = 0,"No Fault", 1,"Short/Overload Fault"; Param31 = $ Short/Overload status of 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #6", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum31 = 0,"No Fault", 1,"Short/Overload Fault"; Param32 = $ Short/Overload status of 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 70", $ Link Path to DOP object's Short attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Short/Overload Status #7", $ Parameter Name "", $ Units String "Short circuit or Overload status bit.\nError only detected in the ON state.\n\nPossible faults:\n - short circuit (0 ohm load)\n - too much current (greater than rated output current)\n - no field power\n\nError may be latched by Reset Mode ('latched off') or latching of alarms", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum32 = 0,"No Fault", 1,"Short/Overload Fault"; $ Group Status Param33 = $ Status of Output Group 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 05", $ Link Path to DOG object's status attribute. 0x0032, $ No support for: settable path, scaling, scaling links. $ Real time update of value. Value is gettable only. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Output Group Status", $ Parameter Name "", $ Units String "This Status bit is the OR of all possible faults for ALL channels.\n\nPossible Faults:\n - open load\n - short circuit\n - over current\n - no field power\n\nNote: Status could be 'latched' in fault state.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum33 = 0,"No Fault", 1,"FAULT"; $ Clear Latched Alarm Param34 = $ Clear latached alarms 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #0", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum34 = 0,"Do Nothing", 1,"Clear Alarms"; Param35 = $ Clear latached alarms 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #1", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum35 = 0,"Do Nothing", 1,"Clear Alarms"; Param36 = $ Clear latached alarms 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #2", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum36 = 0,"Do Nothing", 1,"Clear Alarms"; Param37 = $ Clear latached alarms 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #3", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum37 = 0,"Do Nothing", 1,"Clear Alarms"; Param38 = $ Clear latached alarms 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #4", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum38 = 0,"Do Nothing", 1,"Clear Alarms"; Param39 = $ Clear latached alarms 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #5", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum39 = 0,"Do Nothing", 1,"Clear Alarms"; Param40 = $ Clear latached alarms 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #6", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum40 = 0,"Do Nothing", 1,"Clear Alarms"; Param41 = $ Clear latached alarms 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 67", $ Link Path to DOP object's Clear Latched alarm Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Clear Latched Alarms #7", $ Parameter Name "", $ Units String "This service will clear all latched alarms in the output point.\nIf Latching of Alarms is not enabled for this channel, this service will have no effect.\nIf the fault still exists, it will be latched again.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum41 = 0,"Do Nothing", 1,"Clear Alarms"; $ Group Run/Idle Command Param42 = $ Group Run/Idle Command 0, $ reserved 6, $ Link Path Size "20 1E 24 01 30 06", $ Link Path to DOG object's Command Attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Group Run/Idle Command", $ Parameter Name "", $ Units String "Puts all outputs in Idle mode.\nOutput state will be determined by the Idle State parameter. \nNote: Only works when NOT in a scanner's scanlist.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum42 = 0,"Idle", 1,"Run"; $ Fault Values Param43 = $ Fault State selection for output 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Action #0", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum43 = 0,"Fault Value", 1,"Hold Last State"; Param44 = $ Fault Value selection for output 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #0", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum44 = 0,"OFF", 1,"ON"; Param45 = $ Fault State selection for output 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Action #1", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum45 = 0,"Fault Value", 1,"Hold Last State"; Param46 = $ Fault Value selection for output 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #1", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum46 = 0,"OFF", 1,"ON"; Param47 = $ Fault State selection for output 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean 1, $ Data Size "Fault Action #2", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum47 = 0,"Fault Value", 1,"Hold Last State"; Param48 = $ Fault Value selection for output 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #2", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum48 = 0,"OFF", 1,"ON"; Param49 = $ Fault State selection for output 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Action #3", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum49 = 0,"Fault Value", 1,"Hold Last State"; Param50 = $ Fault Value selection for output 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #3", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum50 = 0,"OFF", 1,"ON"; Param51 = $ Fault State selection for output 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Action #4", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum51 = 0,"Fault Value", 1,"Hold Last State"; Param52 = $ Fault Value selection for output 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #4", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum52 = 0,"OFF", 1,"ON"; Param53 = $ Fault State selection for output 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Action #5", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum53 = 0,"Fault Value", 1,"Hold Last State"; Param54 = $ Fault Value selection for output 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #5", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum54 = 0,"OFF", 1,"ON"; Param55 = $ Fault State selection for output 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean 1, $ Data Size "Fault Action #6", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum55 = 0,"Fault Value", 1,"Hold Last State"; Param56 = $ Fault Value selection for output 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #6", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum56 = 0,"OFF", 1,"ON"; Param57 = $ Fault State selection for output 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 05", $ Link Path to DOP object's fault action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Action #7", $ Parameter Name "", $ Units String "Fault Action defines output behavior in the event of a communication fault.\n\nPossible States:\n - goto Fault Value (defined in Fault Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum57 = 0,"Fault Value", 1,"Hold Last State"; Param58 = $ Fault Value selection for output 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 06", $ Link Path to DOP object's fault value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Fault Value #7", $ Parameter Name "", $ Units String "If 'Fault Value' is selected for this channel (in Fault Action parameter),\nthis field defines the output value during a fault.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum58 = 0,"OFF", 1,"ON"; $ Idle Values Param59 = $ Idle State selection for output 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #0", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum59 = 0,"Idle Value", 1,"Hold Last State"; Param60 = $ Idle Value selection for output 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #0", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum60 = 0,"OFF", 1,"ON"; Param61 = $ Idle State selection for output 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #1", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum61 = 0,"Idle Value", 1,"Hold Last State"; Param62 = $ Idle Value selection for output 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #1", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum62 = 0,"OFF", 1,"ON"; Param63 = $ Idle State selection for output 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #2", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum63 = 0,"Idle Value", 1,"Hold Last State"; Param64 = $ Idle Value selection for output 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #2", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum64 = 0,"OFF", 1,"ON"; Param65 = $ Idle State selection for output 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #3", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum65 = 0,"Idle Value", 1,"Hold Last State"; Param66 = $ Idle Value selection for output 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #3", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum66 = 0,"OFF", 1,"ON"; Param67 = $ Idle State selection for output 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #4", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum67 = 0,"Idle Value", 1,"Hold Last State"; Param68 = $ Idle Value selection for output 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #4", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum68 = 0,"OFF", 1,"ON"; Param69 = $ Idle State selection for output 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #5", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum69 = 0,"Idle Value", 1,"Hold Last State"; Param70 = $ Idle Value selection for output 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #5", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum70 = 0,"OFF", 1,"ON"; Param71 = $ Idle State selection for output 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #6", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum71 = 0,"Idle Value", 1,"Hold Last State"; Param72 = $ Idle Value selection for output 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #6", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum72 = 0,"OFF", 1,"ON"; Param73 = $ Idle State selection for output 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 07", $ Link Path to DOP object's idle action attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Action #7", $ Parameter Name "", $ Units String "Idle Action defines output behavior during program or idle mode.\n\nPossible States:\n - goto Idle Value (defined in Idle Value parameter)\n - Hold Last State (state of output is uneffected by fault)", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum73 = 0,"Idle Value", 1,"Hold Last State"; Param74 = $ Idle Value selection for output 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 08", $ Link Path to DOP object's idle value attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Idle Value #7", $ Parameter Name "", $ Units String "If 'Idle Value' is selected for this channel (in Idle Action parameter),\nthis field defines the output value during a Idle or Program mode.\n - ON\n - OFF", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum74 = 0,"OFF", 1,"ON"; $ Enable Latched Alarms Param75 = $ Enable Latched Alarms for output 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #0", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum75 = 0,"Latching Disabled", 1,"Latching Enabled"; Param76 = $ Enable Latched Alarms for output 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #1", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum76 = 0,"Latching Disabled", 1,"Latching Enabled"; Param77 = $ Enable Latched Alarms for output 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #2", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum77 = 0,"Latching Disabled", 1,"Latching Enabled"; Param78 = $ Enable Latched Alarms for output 3 0, $ reserved 6, $ Link Path Size "20 09 24 04 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #3", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum78 = 0,"Latching Disabled", 1,"Latching Enabled"; Param79 = $ Enable Latched Alarms for output 4 0, $ reserved 6, $ Link Path Size "20 09 24 05 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #4", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum79 = 0,"Latching Disabled", 1,"Latching Enabled"; Param80 = $ Enable Latched Alarms for output 5 0, $ reserved 6, $ Link Path Size "20 09 24 06 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #5", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum80 = 0,"Latching Disabled", 1,"Latching Enabled"; Param81 = $ Enable Latched Alarms for output 6 0, $ reserved 6, $ Link Path Size "20 09 24 07 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #6", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum81 = 0,"Latching Disabled", 1,"Latching Enabled"; Param82 = $ Enable Latched Alarms for output 7 0, $ reserved 6, $ Link Path Size "20 09 24 08 30 68", $ Link Path to DOP object's latch alarm enable attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable Latching Alarms #7", $ Parameter Name "", $ Units String "This parameter selects how a status bit acts after the cause of the fault is removed.\nIf 'Latching Enabled,' alarm bits will stay FAULTed if an alarm occurs.\nThe FAULT can only be cleared using the Clear Latched Alarm service for this point.\nLatching is useful for tracking transient or momentary faults.\nIf 'Latching Disabled,' alarms will refect the present state.\n\nNote: LEDs don't reflect latched Alarms.", 0,1,0, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum82 = 0,"Latching Disabled", 1,"Latching Enabled"; $ Enable No Load Param83 = $ Enable No Load for output 0 0, $ reserved 6, $ Link Path Size "20 09 24 01 30 6A", $ Link Path to DOP object's Enable No Load attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable No Load #0", $ Parameter Name "", $ Units String "This parameter turns on and off No Load Detection.\nDisabling the No Load diagnostic is useful for unused channels.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum83 = 0,"No Load Disabled", 1,"No Load Enabled"; Param84 = $ Enable No Load for output 1 0, $ reserved 6, $ Link Path Size "20 09 24 02 30 6A", $ Link Path to DOP object's Enable No Load attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0xC1, $ Data Type - boolean (New data type) 1, $ Data Size "Enable No Load #1", $ Parameter Name "", $ Units String "This parameter turns on and off No Load Detection.\nDisabling the No Load diagnostic is useful for unused channels.", 0,1,1, $ Min, Max (max enumeration #), and Default values 1,1,1,0,0,0,0,0,0; $ Not Used Enum84 = 0,"No Load Disabled", 1,"No Load Enabled"; Param85 = $ Enable No Load for output 2 0, $ reserved 6, $ Link Path Size "20 09 24 03 30 6A", $ Link Path to DOP object's Enable No Load attribute. 0x0002, $ No support for: settable path, scaling, scaling links, or $ real time update of value. Value is gettable and $ Settable. Enumerated strings are supported. 0x